Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Public Health ; 226: 152-156, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38064778

RESUMO

OBJECTIVES: Emissions from road traffic, power generation and industry were substantially reduced during pandemic lockdown periods globally. Thus, we analysed reductions in traffic-related air pollution in Australian capital cities during March-April 2020 and then modelled the mortality benefits that could be realised if similar reductions were sustained by structural policy interventions. STUDY DESIGN: Satellite, air pollution monitor and land use observations were used to estimate ground-level nitrogen dioxide (NO2) concentrations in all Australian capital cities during: (a) a typical year with no prolonged air pollution events; (b) a hypothetical sustained reduction in NO2 equivalent to the COVID-19 lockdowns. METHODS: We use the WHO recommended NO2 exposure-response coefficient for mortality (1.023, 95 % CI: 1.008-1.037, per 10 µg/m3 annual average) to assess gains in life expectancy and population-wide years of life from reduced exposure to traffic-related air pollution. RESULTS: We attribute 1.1 % of deaths to anthropogenic NO2 exposures in Australian cities, corresponding to a total of 13,340 years of life lost annually. Although COVID-19-related reductions in NO2 varied widely between Australian cities during April 2020, equivalent and sustained reductions in NO2 emissions could reduce NO2-attributable deaths by 27 %, resulting in 3348 years of life gained annually. CONCLUSIONS: COVID-19 mobility restrictions reduced NO2 emissions and population-wide exposures in Australian cities. When sustained to the same extent by policy interventions that reduce fossil fuel consumption by favouring the uptake of electric vehicles, active travel and public transport, the health, mortality and economic benefits will be measurable in Australian cities.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , COVID-19 , Humanos , Poluentes Atmosféricos/análise , Cidades , Emissões de Veículos , Dióxido de Nitrogênio/análise , COVID-19/prevenção & controle , Austrália/epidemiologia , Controle de Doenças Transmissíveis , Poluição do Ar/análise , Material Particulado/análise , Monitoramento Ambiental/métodos
2.
J Hosp Infect ; 132: 133-139, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36309203

RESUMO

BACKGROUND: Mycobacterium abscessus (MABS) group are environmental organisms that can cause infection in people with cystic fibrosis (CF) and other suppurative lung diseases. There is potential for person-to-person airborne transmission of MABS among people with CF attending the same care centre. Ultraviolet light (band C, UV-C) is used for Mycobacterium tuberculosis control indoors; however, no studies have assessed UV-C for airborne MABS. AIM: To determine whether a range of UV-C doses increased the inactivation of airborne MABS, compared with no-UVC conditions. METHODS: MABS was generated by a vibrating mesh nebulizer located within a 400 L rotating drum sampler, and then exposed to an array of 265 nm UV-C light-emitting diodes (LED). A six-stage Andersen Cascade Impactor was used to collect aerosols. Standard microbiological protocols were used for enumerating MABS, and these quantified the effectiveness of UV-C doses (in triplicate). UV-C effectiveness was estimated using the difference between inactivation with and without UV-C. FINDINGS: Sixteen tests were performed, with UV-C doses ranging from 276 to 1104 µW s/cm2. Mean (±SD) UV-C effectiveness ranged from 47.1% (±13.4) to 83.6% (±3.3). UV-C led to significantly greater inactivation of MABS (all P-values ≤0.045) than natural decay at all doses assessed. Using an indoor model of the hospital environment, it was estimated that UV-C doses in the range studied here could be safely delivered in clinical settings where patients and staff are present. CONCLUSION: This study provides empirical in-vitro evidence that nebulized MABS are susceptible to UV-C inactivation.


Assuntos
Mycobacterium abscessus , Mycobacterium tuberculosis , Humanos , Raios Ultravioleta , Aerossóis e Gotículas Respiratórios , Desinfecção/métodos
3.
Sci Total Environ ; 809: 151158, 2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-34695471

RESUMO

The 2020 COVID-19 outbreak in New South Wales (NSW), Australia, followed an unprecedented wildfire season that exposed large populations to wildfire smoke. Wildfires release particulate matter (PM), toxic gases and organic and non-organic chemicals that may be associated with increased incidence of COVID-19. This study estimated the association of wildfire smoke exposure with the incidence of COVID-19 in NSW. A Bayesian mixed-effect regression was used to estimate the association of either the average PM10 level or the proportion of wildfire burned area as proxies of wildfire smoke exposure with COVID-19 incidence in NSW, adjusting for sociodemographic risk factors. The analysis followed an ecological design using the 129 NSW Local Government Areas (LGA) as the ecological units. A random effects model and a model including the LGA spatial distribution (spatial model) were compared. A higher proportional wildfire burned area was associated with higher COVID-19 incidence in both the random effects and spatial models after adjustment for sociodemographic factors (posterior mean = 1.32 (99% credible interval: 1.05-1.67) and 1.31 (99% credible interval: 1.03-1.65), respectively). No evidence of an association between the average PM10 level and the COVID-19 incidence was found. LGAs in the greater Sydney and Hunter regions had the highest increase in the risk of COVID-19. This study identified wildfire smoke exposures were associated with increased risk of COVID-19 in NSW. Research on individual responses to specific wildfire airborne particles and pollutants needs to be conducted to further identify the causal links between SARS-Cov-2 infection and wildfire smoke. The identification of LGAs with the highest risk of COVID-19 associated with wildfire smoke exposure can be useful for public health prevention and or mitigation strategies.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , COVID-19 , Incêndios Florestais , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Austrália , Teorema de Bayes , Exposição Ambiental , Humanos , Incidência , New South Wales/epidemiologia , Material Particulado/análise , SARS-CoV-2 , Fumaça/efeitos adversos , Fatores Sociodemográficos
4.
J Hosp Infect ; 103(2): 175-184, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31279762

RESUMO

Healthcare-acquired infections (HAIs) continue to persist in hospitals, despite the use of increasingly strict infection-control precautions. Opportunistic airborne transmission of potentially pathogenic bioaerosols may be one possible reason for this persistence. Therefore, this study aimed to systematically review the concentrations and compositions of indoor bioaerosols in different areas within hospitals and the effects of different ventilation systems. Electronic databases (Medline and Web of Science) were searched to identify articles of interest. The search was restricted to articles published from 2000 to 2017 in English. Aggregate data was used to examine the differences in mean colony forming units per cubic metre (cfu/m3) between different hospital areas and ventilation types. A total of 36 journal articles met the eligibility criteria. The mean total bioaerosol concentrations in the different areas of the hospitals were highest in the inpatient facilities (77 cfu/m3, 95% confidence interval (CI): 55-108) compared with the restricted (13cfu/m3, 95% CI: 10-15) and public areas (14 cfu/m3, 95% CI: 10-19). Hospital areas with natural ventilation had the highest total bioaerosol concentrations (201 cfu/m3, 95% CI: 135-300) compared with areas using conventional mechanical ventilation systems (20 cfu/m3, 95% CI: 16-24). Hospital areas using sophisticated mechanical ventilation systems (such as increased air changes per hour, directional flow and filtration systems) had the lowest total bioaerosol concentrations (9 cfu/m3, 95% CI: 7-13). Operating sophisticated mechanical ventilation systems in hospitals contributes to improved indoor air quality within hospitals, which assists in reducing the risk of airborne transmission of HAIs.


Assuntos
Aerossóis , Microbiologia do Ar , Hospitais , Ventilação , Poluição do Ar em Ambientes Fechados , Contagem de Colônia Microbiana , Humanos
5.
Indoor Air ; 27(5): 988-1000, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28303606

RESUMO

Fluorescent particles can be markers of bioaerosols and are therefore relevant to nosocomial infections. To date, little research has focused on fluorescent particles in occupied indoor environments, particularly hospitals. In this study, we aimed to determine the spatial and temporal variation of fluorescent particles in two large hospitals in Brisbane, Australia (one for adults and one for children). We used an Ultraviolet Aerodynamic Particle Sizer (UVAPS) to identify fluorescent particle sources, as well as their contribution to total particle concentrations. We found that the average concentrations of both fluorescent and non-fluorescent particles were higher in the adults' hospital (0.06×106 and 1.20×106  particles/m3 , respectively) than in the children's hospital (0.03×106 and 0.33×106  particles/m3 , respectively) (P<.01). However, the proportion of fluorescent particles was higher in the children's hospital. Based on the concentration results and using activity diaries, we were able to identify sources of particle production within the two hospitals. We demonstrated that particles can be easily generated by a variety of everyday activities, which are potential sources of exposure to pathogens. Future studies to further investigate their role in nosocomial infection are warranted.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Poluição do Ar em Ambientes Fechados/análise , Infecção Hospitalar/transmissão , Fluorescência , Hospitais/classificação , Austrália , Monitoramento Ambiental , Fatores de Tempo
6.
Indoor Air ; 27(1): 160-168, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26878824

RESUMO

Although many studies have reported the health effects of biomass fuels in developing countries, relatively few have quantitatively characterized emissions from biomass stoves during cooking and heating. The aim of this pilot study was to characterize the emission characteristics of different biomass stoves in four rural houses in Bhutan during heating (metal chimney stove), rice cooking (traditional mud stove), fodder preparation (stone tripod stove), and liquor distillation (traditional mud stove). Three stage measurements (before, during, and after the activity had ceased) were conducted for PM2.5 , particle number (PN), CO, and CO2 . When stoves were operated, the pollutant concentrations were significantly elevated above background levels, by an average of 40 and 18 times for PM2.5 and CO, respectively. Emission rates (mg/min) ranged from 1.07 × 102 (PM2.5 ) and 3.50 × 102 (CO) for the stone tripod stove during fodder preparation to 6.20 × 102 (PM2.5 ) and 2.22 × 103 (CO) for the traditional mud stove during liquor distillation. Usable PN data were only available for one house, during heating using a metal chimney stove, which presented an emission rate of 3.24 × 1013 particles/min. Interventions to control household air pollution in Bhutan, in order to reduce the health risks associated with cooking and heating, are recommended.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Culinária/métodos , Exposição Ambiental/análise , Calefação/métodos , Habitação , Butão , Biomassa , Dióxido de Carbono/análise , Monóxido de Carbono/análise , Culinária/instrumentação , Humanos , Material Particulado/análise , Projetos Piloto , População Rural
7.
Indoor Air ; 26(4): 623-33, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26182955

RESUMO

Correctional centers (prisons) are one of the few non-residential indoor environments where smoking is still permitted. However, few studies have investigated indoor air quality (IAQ) in these locations. We quantified the level of inmate and staff exposure to secondhand smoke, including particle number (PN) count, and we assessed the impact of the smoking ban on IAQ. We performed measurements of indoor and outdoor PM2.5 and PN concentrations, personal PN exposure levels, volatile organic compounds (VOCs), and nicotine both before and after a complete indoor smoking ban in an Australian maximum security prison. Results show that the indoor 24-h average PM2.5 concentrations ranged from 6 (±1) µg/m(3) to 17 (±3) µg/m(3) pre-ban. The post-ban levels ranged from 7 (±2) µg/m(3) to 71 (±43) µg/m(3) . While PM2.5 concentrations decreased in one unit post-ban, they increased in the other two units. Similar post-ban increases were also observed in levels of PN and VOCs. We describe an unexpected increase of indoor pollutants following a total indoor smoking ban in a prison that was reflected across multiple pollutants that are markers of smoking. We hypothesise that clandestine post-ban smoking among inmates may have been the predominant cause.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/estatística & dados numéricos , Prisões/legislação & jurisprudência , Política Antifumo , Poluição por Fumaça de Tabaco/análise , Austrália , Humanos , Nicotina/análise , Material Particulado/análise , Compostos Orgânicos Voláteis/análise
8.
Indoor Air ; 25(5): 462-74, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25346039

RESUMO

There is an ongoing debate about the reasons for and factors contributing to healthcare-associated infection (HAI). Different solutions have been proposed over time to control the spread of HAI, with more focus on hand hygiene than on other aspects such as preventing the aerial dissemination of bacteria. Yet, it emerges that there is a need for a more pluralistic approach to infection control; one that reflects the complexity of the systems associated with HAI and involves multidisciplinary teams including hospital doctors, infection control nurses, microbiologists, architects, and engineers with expertise in building design and facilities management. This study reviews the knowledge base on the role that environmental contamination plays in the transmission of HAI, with the aim of raising awareness regarding infection control issues that are frequently overlooked. From the discussion presented in the study, it is clear that many unknowns persist regarding aerial dissemination of bacteria, and its control via cleaning and disinfection of the clinical environment. There is a paucity of good-quality epidemiological data, making it difficult for healthcare authorities to develop evidence-based policies. Consequently, there is a strong need for carefully designed studies to determine the impact of environmental contamination on the spread of HAI.


Assuntos
Microbiologia do Ar , Infecção Hospitalar/transmissão , Infecções Bacterianas/transmissão , Humanos , Controle de Infecções , Micoses/transmissão , Ventilação/instrumentação
9.
Environ Int ; 49: 110-4, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23010254

RESUMO

Exposures to traffic-related air pollution (TRAP) can be particularly high in transport microenvironments (i.e. in and around vehicles) despite the short durations typically spent there. There is a mounting body of evidence that suggests that this is especially true for fine (<2.5 µm) and ultrafine (<100 nm, UF) particles. Professional drivers, who spend extended periods of time in transport microenvironments due to their job, may incur exposures markedly higher than already elevated non-occupational exposures. Numerous epidemiological studies have shown a raised incidence of adverse health outcomes among professional drivers, and exposure to TRAP has been suggested as one of the possible causal factors. Despite this, data describing the range and determinants of occupational exposures to fine and UF particles are largely conspicuous in their absence. Such information could strengthen attempts to define the aetiology of professional drivers' illnesses as it relates to traffic combustion-derived particles. In this article, we suggest that the drivers' occupational fine and UF particle exposures are an exemplar case where opportunities exist to better link exposure science and epidemiology in addressing questions of causality. The nature of the hazard is first introduced, followed by an overview of the health effects attributable to exposures typical of transport microenvironments. Basic determinants of exposure and reduction strategies are also described, and finally the state of knowledge is briefly summarised along with an outline of the main unanswered questions in the topic area.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar/estatística & dados numéricos , Exposição Ocupacional/estatística & dados numéricos , Material Particulado/análise , Emissões de Veículos/análise , Poluição do Ar/efeitos adversos , Condução de Veículo/estatística & dados numéricos , Humanos , Doenças Profissionais/epidemiologia , Fatores de Tempo
10.
Epidemiol Infect ; 140(3): 474-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21733264

RESUMO

Travel in passenger cars is a ubiquitous aspect of the daily activities of many people. During the 2009 influenza A(H1N1) pandemic a case of probable transmission during car travel was reported in Australia, to which spread via the airborne route may have contributed. However, there are no data to indicate the likely risks of such events, and how they may vary and be mitigated. To address this knowledge gap, we estimated the risk of airborne influenza transmission in two cars (1989 model and 2005 model) by employing ventilation measurements and a variation of the Wells-Riley model. Results suggested that infection risk can be reduced by not recirculating air; however, estimated risk ranged from 59% to 99·9% for a 90-min trip when air was recirculated in the newer vehicle. These results have implications for interrupting in-car transmission of other illnesses spread by the airborne route.


Assuntos
Microbiologia do Ar , Automóveis , Influenza Humana/transmissão , Austrália , Humanos , Medição de Risco
11.
Indoor Air ; 19(4): 303-13, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19500174

RESUMO

UNLABELLED: For many people, a relatively large proportion of daily exposure to a multitude of pollutants may occur inside an automobile. A key determinant of exposure is the amount of outdoor air entering the cabin (i.e. air change or flow rate). We have quantified this parameter in six passenger vehicles ranging in age from 18 years to <1 year, at three vehicle speeds and under four different ventilation settings. Average infiltration into the cabin with all operable air entry pathways closed was between 1 and 33.1 air changes per hour (ACH) at a vehicle speed of 60 km/h, and between 2.6 and 47.3 ACH at 110 km/h, with these results representing the most (2005 Volkswagen Golf) and least air-tight (1989 Mazda 121) vehicles, respectively. Average infiltration into stationary vehicles parked outdoors varied between approximately 0 and 1.4 ACH and was moderately related to wind speed. Measurements were also performed under an air recirculation setting with low fan speed, while airflow rate measurements were conducted under two non-recirculate ventilation settings with low and high fan speeds. The windows were closed in all cases, and over 200 measurements were performed. The results can be applied to estimate pollutant exposure inside vehicles. PRACTICAL IMPLICATIONS: There is increasing recognition of the often disproportionately large contribution of in-vehicle pollutant exposures to overall measures. This has highlighted the need for accurate and representative quantification of determinant factors to facilitate exposure estimation and mitigation. The ventilation rate in a vehicle cabin is a key parameter affecting the transfer of pollutants from outdoors to the cabin interior, and vice-versa. New data regarding this variable are presented here, and the results indicate substantial variability in outdoor air infiltration into vehicles of differing age. The efficacy of simple measures to reduce outdoor air infiltration into 'leaky' vehicles to increase occupant protection would be a worthwhile avenue of further research.


Assuntos
Movimentos do Ar , Poluição do Ar em Ambientes Fechados/análise , Automóveis , Poluentes Atmosféricos , Austrália , Ventilação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...